¥ 7850.00
¥ 7850.00
¥ 7850.00
易卖工控网(www.ymgk.com)提供”A-B 80190-378-52/08 系列伺服电机 库存现货”,产品详情:品牌/厂家:A-B、型号:A-B 80190-378-52/08、成色:全新、货期:现货 1天内发货、保修:180天,更多产品详情就上易卖工控网。
注;本站所有产品均为特殊产品,市场价格一直波动,具体以客服报价为准,因产品为全新产品,图片并非实拍,下单前请跟客服确认型号和产品,价格等详细信息,站内二手,全新均有销售,具体请联系客服沟通。
★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★
我们会让时间证明,您的选择没有错! 我们会用诚心的服务换取您200%的满意
高品质低价格 现货提供 您的满意是我们为之努力的目标
第壹次合作客户,订货前可提供资质及近销售开出的票据扫描件以供查询。
售后问题:按照品牌所属生产厂家标准执行,保证售后服务,所有产品一年质保等
★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★
全新现货,库存充足
质保一年,竭诚售后
本公司专注于DCS、PLC、机器人、大型伺服四大系统领域
主营产品各种模块/卡件,控制器,触摸屏,伺服驱动器
公司优势:供应进口原装正品,专业停产配件
发货快,货期精准,一手货源,现货库存超过1亿
以下是我司【主营产品】,有需要可以发来帮您对比下价格哦!
主营:
①ABB AC800M系列模块,工业机器人零配件DSQCseries, Bailey INFI 90, 800xA,
Advant OCS with Master Software, with MOD 300software Advant OCS, Freelance –过程工业分布式控制系统,Symphony Melody, Satt OCS, Symphony DCI System Six,Harmony/ INFI 90,安全系统
②Schneider(施耐德电气)140系列产品CPU模块
③General electric(通用电气)系列产品 IC693 IC695 IC697 IC698
继电保护SR469开头 SR369开头 SR489开头 SR750开头
IS200/IS215/IS220/IS420/DS200/DS215/VMIVME开头 7750 7807
④Ticonex (英维思)系列产品 3721,3503,4351B,3625,3009
⑤Bently (本特利)3500系列大卡小卡 1900系列电源模块
3500/15 3500/20 3500/22M 3500/42M 3500/25 3500/32 3500/53
⑥Allen-Bradley(美国AB)系列产品1394开头2711开头1756,1747等
⑦ EMERSON /Westinghouse(艾默生美国西屋)系列产品OVATION系统、WDPF系统、MAX0系统备件。
DELTAV德尔塔夫VE3008/CE3008 /SE3008/VE3007/VE3006 SE4006P2
⑧Foxboro(福克斯波罗):I/A Series系统,FBM(现场输入/输出模块)顺序控制、梯形逻辑控制、事故追忆处理、数模转换、输入/输出信号处理、数据通信及处理等 FCP270/FCP280/FBM201…FBM242
⑨Woodword 9907-167 9907-164 9907-165 5464-414 5466-316 5501-467 5501-开头 8444-开头
⑩Bosch Rexroth(博世力士乐):Indramat,I/O模块,PLC控制器,驱动模块等。
Motorola(摩托):MVME 162、MVME 167、MVME5500、MVME6100等系列。
冗余系统介绍
ControlLogix冗余系统由互为冗余的CPU机架、远程I/O 机架及网络附件组成,冗余CPU机架中包括:
◆ 1对电源模块
◆ 1对机架
◆ 至少1对处理器
◆ 至少1对通讯模块
◆ 1对冗余模块 ,冗余模块通过光纤连接。
冗余系统由标准产品组成
◆ 处理器1756-L7x
◆ 以太网模块1756-EN2T、1756-EN2TR、1756-EN2F和1756-EN2TP
◆ ControlNet模块1756-CN2、1756-CN2R
◆ 冗余模块1756-RM2和冗余光纤1756-RMC1
电源
可使用任何ControlLogix电源模块、冗余电源模块或ControlLogix-XT电源模块
处理器
◆ 同一机架只安装2个处理器,处理器必须同系列
◆ 处理器内存必须有足够余量,可以存储2倍的标签数据和2倍的I/O内存
冗余模块
◆ 每个冗余模块有2个千兆单模光口卡,LC接头
◆ 冗余模块安装时尽量靠近处理器
◆ 长距离冗余光纤可自制
采购美国、德国、法国、意大利等欧盟工控产品、备品备件
In order to ensure safety production and realize emergency treatment of emergency accidents, the external automatic tracking regulator is installed on the six regulator circuits. In case of control system failure, the tracking regulator is automatically switched to control the regulating valve independently of DCS; 21 main valves are equipped with emergency treatment button, which is independent of DCS to realize forced switch on the valve. 2.3. hardware configuration:
Omron C200 PLC is selected in the control station, and 9 digital modules (od211/ id212), 4 analog modules (ad003) and 3 regulating modules (pid03) are configured; The operation station adopts Dell opt gx150 computer; The engineer station adopts compa PC. The composition is as follows:
2.4. software configuration of control station:
The configuration of control station is based on the system software SSS of OMRON as the technical platform and ladder diagram as programming tool. The configuration contents are as follows:
2.4.1.allocation of PLC internal address:
I/o address distribution: the i/o address of PLC is the only one-to-one register address for data communication between PLC and field detection equipment and actuator. The allocation of i/o address is the basis for further configuration of PLC; For omron-c200, i/o address is related to the connected i/o module; The i/o address of the field equipment connected to the digital module depends on the installation position and the point number on the module. The i/o address of the field equipment connected to the analog module and PID module depends on the unit number of the i/o module (different modules shall be set with different unit numbers through the hard opening and closing of the module) and the point number on the module; For example, in the configuration of this system, the analog signal of 4-20mA output by the radar level transmitter LT-101 on site is connected to the second point of analog input module ad003 with unit number 3, the address of its configuration in PLC is ir:132; When the closed signal of valve hv120 is connected to the tenth point of the digital input module id212 installed in the second slot of the expansion rack, its configuration address in PLC is ir:01210; In this system, 142 i/o addresses are defined.
购买咨询热线:15339537795(微信同号)
QQ:342289566
联系人:袁小姐
邮箱:342289566@qq.com
公司:贵州源妙自动化设备有限公司
地址:贵州省安顺市西秀区北街街道虹山湖路42号虹山大酒店(百灵.希尔顿逸林酒店 )幢14层9号
ControlNet通讯模块
(新项目推荐采用以太网架构,C网架构会逐渐退出市场舞台)
◆ 大128个CIP连接
◆ 至少使用4个网络节点
◆ 小节点地址分配给远程模块,做为激活的保持器Keeper。
◆ 冗余机架上的ControlNet模块设置相同节点地址,同步以后从站地址会自动加1,要为从站预留连续地址
◆ 支持冗余介质
控制网ControlNet
◆ 总线拓扑,连接同轴电缆、T分支器和终端电阻,ControlNet通讯模块上通道灯应为绿色常亮。
◆ 选择主机架上电,从机架随后上电,下载程序到主处理器,处理器在编程模式。
◆ 使用RSNetWorx for ControlNet软件规划网络。
◆ 将主处理器转到运行模式, ControlNet通讯模块OK灯绿色常亮,I/O模块OK灯绿色常亮,从机架同步。
冗余系统配置
(1):安装软件
◆ 安装RSLogix5000/Studio5000软件,注意版本,RSLinx Classic软件会自动安装。
◆ 如果采用ControlNet架构,安装RSNetWorx for ControlNet软件。
◆ 安装冗余固件包,ControlFlash V14以上或者ControlFlash Plus工具
◆ 安装冗余配置工具RMCT
(2):安装硬件
◆ 将电源模块、处理器、通讯模块和冗余模块安装到机架中。
◆ 两个机架中,相同模块的槽位要一致,建议冗余模块靠近处理器放置。
◆ ControlNet通讯模块节点通过拨码设置。
◆ 冗余模块光纤连接,光口没有顺序要求。
◆ 为电源模块连接电源。
(3):与电脑建立连接
◆ 分别为2个机架上电。
◆ 使用USB电缆将处理器和电脑连接,在RSLinx Classic中可以看到机架和机架上的所有模块。
◆ 在RSLinx Classic中为以太网模块设置IP地址,改为静态。
◆ 也可以使用BootP-DHCP工具直接为以太网模块设置IP地址。
◆ 对应的以太网模块的IP地址、子网掩码、网关要一致。
◆ 在RSLinx Classic中建立Ethernet/IP驱动,可以通过以太网看到机架和机架上的所有模块。
(4):固件刷新
◆ 使用ControlFlash或ControlFlash Plus工具分别刷新机架中的模块。
◆ 需要刷新的版本依据固件包的Release notes。
◆ 2个机架分别上电刷。
◆ 处理器钥匙开关位于REM档。
(5):网络配置以太网Ethernet/IP
◆ 星型拓扑,以太网模块要连接到交换机。
◆ 环型拓扑,设置环网管理者,连接所有DLR环网节点,在RSLinx Classic中查看环网状态。
◆ RSLinx Classic里设置以太网路由
(6):冗余模块配置
◆ 基本使用不需要配置冗余模块。
◆ 建议使用RMCT设置冗余模块时间。
PLC模块,可编程控制器,CPU模块,IO模块,DO模块,AI模块,DI模块,网通信模块,
以太网模块,运动控制模块,模拟量输入模块,模拟量输出模块,数字输入模块,数字输出模块,
冗余模块,电源模块,继电器输出模块,继电器输入模块,处理器模块。