幻花自动化
首页> 幻花自动化> SE4006P2控器模块EMERSON

X

SE4006P2控器模块EMERSON SE4006P2,SE4006P2,SE4006P2
  • SE4006P2控器模块EMERSON SE4006P2,SE4006P2,SE4006P2
  • SE4006P2控器模块EMERSON SE4006P2,SE4006P2,SE4006P2
  • SE4006P2控器模块EMERSON SE4006P2,SE4006P2,SE4006P2
  • SE4006P2控器模块EMERSON SE4006P2,SE4006P2,SE4006P2
  • SE4006P2控器模块EMERSON SE4006P2,SE4006P2,SE4006P2

SE4006P2控器模块EMERSON

产品价格:
¥ 54545.00
立即咨询:
点击这里给我发消息 在线咨询 点击这里给我发消息 QQ咨询
线:
18030177759
联系我时请告诉我是在易卖工控网看到的,谢谢!
牌:
EMERSON/艾默生
号:
SE4006P2
色:
全新 | 保修180天
货:
现货 1天内发货
量:
(库存12件)
诚信认证:
温馨提醒:点击联系方式和卖家进行沟通
在线咨询|QQ咨询|热线拨打!
商家信息
3
主营类目:
PLC
所 在  地:
福建 漳州市 芗城区

易卖工控网(www.ymgk.com)提供”SE4006P2控器模块EMERSON”,产品详情:品牌/厂家:EMERSON/艾默生、型号:SE4006P2、成色:全新、货期:现货 1天内发货、保修:180天,更多产品详情就上易卖工控网。

SE4006P2

实时数据库里添加开关型数据分别为定时器启动、定时器复位、启动、复位、下移夹紧、上移、右移、放松和左移。左工件和右工件。(4)再添加垂直移动量,水平移动量、计时时间和时间到等数据型数据。

(5)在各个图符里添加相关的属性,注意连接管子的两个矩形要合成图符因为要添加“水平移动量”属性。

(6)当相关属性在表达式里从实时策略里选完后,后还要给机械臂添加大小变化的属性,其计算方法为臂伸长后的总长度=臂的实际长度+伸长的量,如何进行长度测量,先画一条直线打开查看栏里的状态条,便会在右下角显示长度,
SE4006P2控器模块EMERSON SE4006P2,SE4006P2,SE4006P2

2个光纤端口至光纤模块总线

模块总线(电气)至I/O模块

I/O模块总线和电源的监控功能

I/O模块的隔离电源

TU840,MTU用于冗余TB840/TB840A,双模块总线

TU841,MTU用于冗余TB840/TB840A,单模块总线

输入电源保险丝
S800 I/O is a comprehensive, distributed and modular process I/O system that communicates with parent controllers and PLCs over industry-standard field buses. The TB840 ModuleBus Modem is a fiber optic interface to the Optical ModuleBus. TB840A is used in redundancy configurations where each module is connected to different optical ModuleBus lines, but connected to the same electrical ModuleBus.
SE4006P2控器模块EMERSON SE4006P2,SE4006P2,SE4006P2
The ModuleBus Modem has an electrical and an optical Modulebus interface which are logically the same bus. A maximum of 12 I/O modules can be connected to the electrical ModuleBus and up to seven clusters can be connected to the fiber optic ModuleBus. The fiber optic interface is intended for local distribution of I/O clusters and where more than 12 I/O modules are required in an I/O station.
SE4006P2控器模块EMERSON SE4006P2,SE4006P2,SE4006P2


Features and benefits
2 fiber optic ports to optical ModuleBus
ModuleBus (electrical) to the I/O Modules
Supervisory functions of I/O ModuleBus and power supply
Isolated power supply to I/O modules
TU840, MTU for redundant TB840/TB840A, dual ModuleBus
TU841, MTU for redundant TB840/TB840A, single ModuleBus
Input power fused
The Hydran M2 is a compact permanently mounted on-line transformer monitoring device that will alert personnel to developing fault conditions. It continuously monitors a composite value of various fault gases (in ppm) or a Hydrogen gas only value (depending on sensor purchased). In addition it tracks moisture in oil (reading in %RH and ppm).
SE4006P2控器模块EMERSON SE4006P2,SE4006P2,SE4006P2


With additional sensors added, the Hydran M2 can also compute transformer mathematical models based on IEEE® and IEC® standards to provide further information on the performance of the transformer.Hydran M2是一种紧凑的安装在线变压器监测装置,可提醒人员出现故障情况。它连续监测各种故障气体的合成值(ppm)或仅氢气值(取决于购买的传感器)。此外,它还跟踪油中的水分(读数为%RH和ppm)。



添加了额外的传感器后,Hydran M2还可以根据IEEE®和IEC®标准计算变压器数学模型,以提供关于变压器性能的进一步信息。Real-time Hydrogen or composite fault gas monitoring system
Moisture in oil measurement
Ability to integrate additional sensors (load, oil temperature, …)
Option to process transformer mathematical models based on IEC/IEEE standardsEasy to install on a single valve.
No moving parts, no pumps and no extra piping required.
No field calibration required.
Local and remote alarms set at pre defined levels.Hydrogen sensor responds 100% to Hydrogen (general fault gas)
Composite gas sensor responds 100% to Hydrogen and is also sensitive to Carbon Dioxide (overheated paper insulation).
Choice of up to 4x input or output cards
Wide range of communication methods and protocols.
RS485 output is standard. TCP/IP copper or fibre is optional
     
Vacuum-resistant gas extraction membrane.
Built in temperature condition system.
Full system self test and self-diagnostics.
Logging of data and significant events up to a year.
User-friendly client/server graphical user interface software.
Applications

Medium to large sized transformers.
Lower risk and/or consequence of failure.
     
Transmission transformers.
Significant step up from manual oil sampling.实时氢气或复合故障气体监测系统

油中水分测量

能够集成附加传感器(负载、油温等)

基于IEC/IEEE标准处理变压器数学模型的选项易于安装在单个阀门上。

无需移动部件、泵和额外管道。

无需现场校准。

本地和远程警报设置在预先定义的水平。氢气传感器100%响应氢气(一般故障气体)

复合气体传感器对氢气100%响应,对二氧化碳(纸绝缘过热)也敏感。

多可选择4个输入或输出卡

广泛的通信方法和协议。

RS485输出为标准输出。TCP/IP铜缆或光纤是可选的



耐真空气体抽取膜。

内置温度调节系统。

全系统自检和自诊断。

记录长达一年的数据和重大事件。

用户友好的客户端/服务器图形用户界面软件。

应用



中大型变压器。

降低故障风险和/或后果。



输电变压器。

手动油取样的显著提高。水流量分析仪CLS204温度控制器204-C10000BY
Watlow Anafaze CLS200操控器204-C10000BY
Watlow Anafaze CLS200操控器的特色:

多达16个加热和冷却回路的PID操控小化了每个回路的面板空间,减少了安装时间,并提高了可靠性:更少的零件意味着更少的毛病
自动调谐需求更少的调谐时间,并以更少的专业知识实现出色的操控
带有全文显现的菜单引导操作答应快速设置操控器并简化操作
八个作业被存储和调用,从一个进程快速转换到另一个进程
多输入和混合输入,接受热电偶、电阻温度传感器、线性直流电压和线性直流电流传感器的组合,并减少学习曲线和库存
传感器毛病检测缩短了对反向、短路和开路传感器、高/低进程和每个输入的偏差警报进行毛病诊断的时间,并根据需求与PLC和其他操控元件集成
34路数字输出,供给灵活的装备,并答应根据操控和报警需求使用输出
EIA/TIA-232和485通信,连接到软件以便于装备和操作,并答应与操控器和软件集成
PMC-5565PIORC 反射式内存节点卡提供高速、低延迟、确定性接口,允许在高达 170 Mbyte/s 的速率下在多达 256 个独立系统(节点)之间共享数据。每个反射内存板都可以配置 128 MB 或 256 MB 的板载 SDRAM。本地 SDRAM 提供对存储数据的快速读取访问时间。写入存储在本地 SDRAM 中,并通过高速光纤数据路径广播到其他反射存储器节点。节点之间的数据传输是软件透明的,因此不需要 I/O 开销。在峰值数据速率期间发送和接收 FIFO 缓冲数据,以优化主机和总线性能以保持高数据吞吐量。PMC-5565PIORC 符合 RoHS 标准,并具有改进的 PIO 读取性能和可在现场升级的固件。
文章来自;https://www.kniocauto.com/S800 I/O is a comprehensive, distributed and modular process I/O system, which communicates with the parent controller and PLC through industrial standard field bus. The TB840 ModuleBus Modem is the optical interface of the optical module bus. The TB840A is used for redundant configuration, where each module is connected to a different optical module bus line, but connected to the same electrical module bus.





The ModuleBus Modem has logically the same electrical and optical ModuleBus interfaces. Up to 12 I/O modules can be connected to the electrical module bus, and up to 7 clusters can be connected to the optical module bus. The optical fiber interface is used for the local distribution of I/O clusters, and more than 12 I/O modules are required in the I/O station.





Features and Benefits



2 optical ports to optical module bus



Module bus (electrical) to I/O modules



Monitoring function of I/O module bus and power supply



Isolated power supply for I/O modules



TU840, MTU for redundant TB840/TB840A, dual module bus



TU841, MTU for redundant TB840/TB840A, single module bus



Input power fuse

S800 I/O is a comprehensive, distributed and modular process I/O system that communicates with parent controllers and PLCs over industry-standard field buses. The TB840 ModuleBus Modem is a fiber optic interface to the Optical ModuleBus. TB840A is used in redundancy configurations where each module is connected to different optical ModuleBus lines, but connected to the same electrical ModuleBus.



The ModuleBus Modem has an electrical and an optical Modulebus interface which are logically the same bus. A maximum of 12 I/O modules can be connected to the electrical ModuleBus and up to seven clusters can be connected to the fiber optic ModuleBus. The fiber optic interface is intended for local distribution of I/O clusters and where more than 12 I/O modules are required in an I/O station.



Features and benefits

2 fiber optic ports to optical ModuleBus

ModuleBus (electrical) to the I/O Modules

Supervisory functions of I/O ModuleBus and power supply

Isolated power supply to I/O modules

TU840, MTU for redundant TB840/TB840A, dual ModuleBus

TU841, MTU for redundant TB840/TB840A, single ModuleBus

Input power fused

The Hydran M2 is a compact permanently mounted on-line transformer monitoring device that will alert personnel to developing fault conditions. It continuously monitors a composite value of various fault gases (in ppm) or a Hydrogen gas only value (depending on sensor purchased). In addition it tracks moisture in oil (reading in %RH and ppm).



With additional sensors added, the Hydran M2 can also compute transformer mathematical models based on IEEE ® and IEC ® standards to provide further information on the performance of the transformer. Hydran M2 is a compact, permanently installed online transformer monitoring device that alerts personnel to a fault condition. It continuously monitors the combined value (ppm) or hydrogen only value of various fault gases (depending on the purchased sensor). In addition, it tracks water in the oil (reading% RH and ppm).





With the addition of additional sensors, Hydran M2 can also ® And IEC ® Standard calculation of the transformer mathematical model to provide further information on transformer performance. Real-time Hydrogen or composite fault gas monitoring system

Moisture in oil measurement

Ability to integrate additional sensors (load, oil temperature, …)

Option to process transformer mathematical models based on IEC/IEEE standardsEasy to install on a single valve.

No moving parts, no pumps and no extra piping required.

No field calibration required.

Local and remote alarms set at pre defined levels. Hydrogen sensor responds 100% to Hydrogen (general fault gas)

Composite gas sensor responds 100% to Hydrogen and is also sensitive to Carbon Dioxide (overheated paper insulation).

Choice of up to 4x input or output cards

Wide range of communication methods and protocols.

RS485 output is standard. TCP/IP copper or fibre is optional



Vacuum-resistant gas extraction membrane.

Built in temperature condition system.

Full system self test and self-diagnostics.

Logging of data and significant events up to a year.

User-friendly client/server graphical user interface software.

Applications



Medium to large sized transformers.

Lower risk and/or consequence of failure.



Transmission transformers.

Significant step up from manual oil sampling



Measurement of moisture in oil



Ability to integrate additional sensors (load, oil temperature, etc.)



The option of handling transformer mathematical models based on IEC/IEEE standards is easy to install on a single valve.



There is no need to move parts, pumps and additional piping.



Field calibration is not required.



Local and remote alarms are set at predefined levels. Hydrogen sensor responds 100% to hydrogen (general fault gas)



The composite gas sensor is 100% responsive to hydrogen and also sensitive to carbon dioxide (paper insulation overheating).



Up to 4 input or output cards can be selected



Extensive communication methods and protocols.



RS485 output is standard output. TCP/IP copper or fiber is optional





Vacuum resistant gas extraction membrane.



Built in temperature regulation system.



Self check and self diagnosis of the whole system.



Record data and major events up to one year.



User friendly client/server graphical user interface software.



application





Medium and large transformers.



Reduce the risk and/or consequences of failure.





Transmission transformer.



Significant improvement in manual oil sampling. Water flow analyzer CLS204 temperature controller 204-C10000BY

Watlow Anafaze CLS200 controller 204-C10000BY

Features of Watlow Anafaze CLS200 controller:



PID control of up to 16 heating and cooling circuits reduces the panel space of each circuit, reduces installation time, and improves reliability: fewer parts mean fewer problems

Automatic tuning requires less tuning time and achieves excellent handling with less expertise

Menu guided operation with full text display allows quick setting of the controller and simplified operation

Eight jobs are stored and called to quickly switch from one process to another

Multi input and mixed input, accept the combination of thermocouple, resistance temperature sensor, linear DC voltage and linear DC current sensor, and reduce the learning curve and inventory

Sensor fault detection shortens the time for fault diagnosis of reverse, short circuit and open circuit sensors, high/low processes and deviation alarms for each input, and integrates with PLC and other control elements as required

34 channel digital output, providing flexible equipment, and allowing the use of output according to control and alarm needs

EIA/TIA-232 and 485 communication, connecting to software for easy equipment and operation, and allowing integration with controller and software

The PMC-5565PIORC reflective memory node card provides a high-speed, low latency, deterministic interface that allows data sharing between up to 256 independent systems (nodes) at a rate of up to 170 Mbyte/s. Each reflective memory board can be configured with 128 MB or 256 MB on-board SDRAM. Local SDRAM provides fast read access time to stored data. Writes are stored in the local SDRAM and broadcast to other reflective memory nodes through high-speed optical fiber data paths. Data transmission between nodes is software transparent, so there is no I/O overhead. Transmit and receive FIFO buffered data during peak data rates to optimize host and bus performance to maintain high data throughput. PMC-5565PIORC conforms to RoHS standard, and has improved PIO reading performance and firmware that can be upgraded in the field.


易卖工控网供应商幻花自动化为您提供SE4006P2控器模块EMERSON的详细产品价格、产品图片等产品介绍信息,您可以直接联系商家获取SE4006P2控器模块EMERSON的具体资料,联系时请说明是在易卖工控网看到的。

安全提示:
请勿随意接收任何来源不明的文件,请勿随意点击任何来源不明的链接。涉及资金往来的事项请务必仔细核对资金往来信息。
内容声明:
易卖工控为第三方交易平台及互联网信息服务提供者,易卖工控所展示的商品/服务的标题、价格、详情等信息内容系由店铺经营者发布,其真实性、准确性和合法性均由店铺经营者负责。易卖提醒用户购买商品/服务前注意谨慎核实。如用户对商品/服务的标题、价格、详情等任何信息有任何疑问的,请在购买前与店铺经营者沟通确认;易卖工控存在海量店铺,如用户发现店铺内有任何违法/侵权信息,请立即向易卖工控举报并提供有效线索。

0

购物车

客服

收藏

公众号

公众号

反馈

︿

顶部

在线联系商家 关闭

幻花自动化

主营类目:PLC热线:18030177759

地址:福建 漳州市 芗城区

点击这里给我发消息在线咨询 点击这里给我发消息QQ咨询