易卖工控网(www.ymgk.com)提供”330500-02-00 Velomitor工业压电速度传感器”,产品详情:品牌/厂家:BENTLY、型号:330500-02-00、成色:全新、货期:现货 1天内发货、保修:180天,更多产品详情就上易卖工控网。
The IC697PWR748 is a 90W 48 VDC Power Supply Module by GE Fanuc for the 90-70 Series. It has three output voltages (+5 VDC output up to 18 amps, +12 VDC output up to 1.5 amps, and -12 VDC output up to 1 amp) totaling 90 watts. The module features slide-in rack mount construction and two rack operation from a single power supply. This power supply is equipped with electronic short circuit overcurrent protection provided on a 5 volt bus.
This particular unit plugs into a 48-pin backplane-mounted connector (see leftmost slot in the rack). It delivers +5 volt, +12 volt, and -12 volt power. Logic level sequencing signals to the backplane. The IC697PWR748 power supply module can be used in a single rack application or, if the user prefers, it can provide power to a second rack. If the latter is chosen, it is important that the total load is within the supply rating.
Interconnection to the second rack is by way of a prewired cable (IC697CBL700). The power supply output will ride through a 10 ms total loss of input power at full load. Protection is delivered for overcurrent and overvoltage fault conditions. The power supply comes standard with an electronic overvoltage protection circuit which will clamp the output if the 5 V bus exceeds 6.7 volts. External overvoltage on the output will not cause the power supply fuse to open, but if an internal fault in the power supply caused the overvoltage condition, it is possible for the fuse to open. If the fuse needs replacement, a 5 amp, 250 volt 5x20 mm fuse should be used.
IC697PWR748是GE Fanuc为90-70系列提供的90W 48 VDC电源模块。它有三个输出电压(+5 VDC输出,高18安培,+12 VDC输出,大1.5安培,-12 VDC输出,多1安培),总计90瓦。该模块具有滑入式机架安装结构和单电源双机架操作。该电源配备了5伏总线上提供的电子短路过电流保护。
此特定单元插入48针背板安装连接器(请参阅机架中左侧的插槽)。它提供+5伏、+12伏和-12伏电源。至背板的逻辑电平排序信号。IC697PWR748电源模块可用于单个机架应用,或者,如果用户愿意,它可以向第二个机架供电。如果选择后者,则总负载必须在额定供电范围内。
通过预布线电缆(IC697CBL700)与第二个机架互连。满载时,电源输出将经历10 ms的输入功率总损失。为过电流和过电压故障条件提供保护。电源标配有一个电子过电压保护电路,如果5V总线超过6.7伏,该电路将箝位输出。输出上的外部过电压不会导致电源保险丝断开,但如果电源中的内部故障导致过电压情况,则保险丝可能断开。如果需要更换保险丝,应使用5安培250伏5x20毫米保险丝。
roduct Description
The GE Fanuc’s IC698RMX016 is a 16MB Redundant Memory Xchange for the Rx7I Pacsystem. It has the following sizing: 6.299 inches widde x 9.187 inches high. It has 16MB of SDRAM user memory. The operating voltage from power supply is +5 V DC. Current requirements are 1.8A. The unit has a fiber optic LC type connector which, conforms to IEC 61754-20, and a zirconium ceramic ferrule. The maximum insertion loss is 0.35 dB with a return loss of -30dB. An acceptable temperature range is between -20°C and +85°C. To complete installation, you need to make sure you have all of the following: A PACSystems RX7i CPU with release 2.00 or later firmware; a PACSystems Rx7i CPU rack with power supply; a PC-compatible computer with CIMPLICITY Machine Edition – Logic Developer PLC, version 4.5 or later programming software and the necessary cables.
Note that in order to meet radiated emission standards, RX7i systems that include more than one Memory Xchange modules have to be installed in a conducting metal enclosure, or equivalent. Memory modules should only be installed in RX7i Rack 0 (main). It is advised that RMX modules are installed in slots 4 and 3 of the main rack. This provides the RMX modules VME interrupt request priority. Although such configuration is advisable, locating RMX modules in slots 4 and 3 is not strictly required. To install IC698RMX016 Redundant Memory Xchange, make sure the rack power is switched off. Next slide the module into the exact slot it was configured for in the system. Proceed to press the board in place without forcing it. Tighten faceplate top and bottom screws. Next make sure to connect cables to RX and TX connectors. The fiber optic cable should be routed from the TX connector to next node’s RX connector. Connect the that board’s TX cable to next node’s RX connector. Repeat until last node in the ring has its TX routed to the RX connector of the first node. Turn the power on.
The IC698RMX016 initially powers in a non-configured state where its optical transmitter is disabled. The Redundant Memory Xchange module will not operate on a network before the RX7i CPU sends the module a hardware configuration. For the purpose of reflective memory operation, the user can choose to configure the following parameters: Redundant Transfer Mode, Node ID, Network Memory Offset, Rogue Master, and Interrupt enable. Note that if the Redundant Link operation is selected, the above-mentioned parameters will be set by the CPU and are therefore not configurable. Note that when IC698RMX016 is used as a reflective memory module with a general purpose, additional functions that extend beyond the basic read and write operations, inclusive of reading interrupt status, enabling interrupts, reading parity errors, and enabling parity may be performed by user logic.
产品描述
GE Fanuc的IC698RMX016是Rx7I Pacsystem的16MB冗余存储器Xchange。其尺寸如下:宽6.299英寸x高9.187英寸。它有16MB的SDRAM用户内存。电源的工作电压为+5 V DC。电流要求为1.8A。该装置具有符合IEC 61754-20的光纤LC型连接器和锆陶瓷套管。大插入损耗为0.35dB,回波损耗为-30dB。可接受的温度范围在-20°C和+85°C之间。要完成安装,您需要确保您具备以下所有功能:PACSystems RX7i CPU,固件版本为2.00或更高版本;带电源的PACSystems Rx7i CPU机架;带有CIMPLICITY Machine Edition–Logic Developer PLC、4.5版或更高版本编程软件和必要电缆的PC兼容计算机。
请注意,为了满足辐射发射标准,包含多个Memory Xchange模块的RX7i系统必须安装在导电金属外壳或等效物中。内存模块只能安装在RX7i机架0(主)中。建议将RMX模块安装在主机架的插槽4和3中。这提供了RMX模块VME中断请求优先级。尽管这种配置是可取的,但不严格要求将RMX模块定位在插槽4和3中。要安装IC698RMX016冗余内存Xchange,请确保机架电源已关闭。然后将模块滑入系统中配置的插槽。继续按压电路板,不要用力。拧紧面板顶部和底部螺钉。接下来,确保将电缆连接到RX和TX连接器。光纤电缆应从TX连接器布线至下一节点的RX连接器。将该板的TX电缆连接到下一节点的RX连接器。重复此操作,直到环中的后一个节点将其TX路由到个节点的RX连接器。打开电源。
IC698RMX016初在非配置状态下通电,其中其光发射器被禁用。在RX7i CPU向模块发送硬件配置之前,冗余存储器Xchange模块不会在网络上运行。为了实现反射内存操作,用户可以选择配置以下参数:冗余传输模式、节点ID、网络内存偏移、Rogue Master和中断启用。注意,如果选择冗余链路操作,上述参数将由CPU设置,因此不可配置。注意,当IC698RMX016用作具有通用目的的反射存储器模块时,用户逻辑可以执行扩展到基本读写操作之外的附加功能,包括读取中断状态、启用中断、读取奇偶校验错误和启用奇偶校验。
Description
The 3500/92 Communication Gateway module providesextensive communication capabilities of all rack monitoredvalues and statuses for integration with process control andother automation systems using both Ethernet TCP/IP andserial (RS232/RS422/RS485)communications capabilities. Italso permits Ethernet communications with 3500 RackConfiguration Software and Data Acquisition Software.supported protocols include:Modicon Modbus protocol (via serialcommunications)Modbus/TCP protocol (a variant of serial Modbus usedfor TCP/IP Ethernet communications )Proprietary Bently Nevada protocol (forcommunication with 3500 Rack Configuration andData Acquisition Software packages)The Ethernet connection to the 3500/92 is an RJ45connection for 10BASE-T star configuration Ethernetnetworks.The 3500/92 supports the communication interfaces,
communication protocols, and other features from theoriginal 3500/90 with the exception of the primary valueModbus registers. The 3500/92 now has a ConfigurableModbus Register Utility, which can provide the samefunctionality originally addressed by the primary valueModbus registers.
描述
3500/92通信网关模块使用以太网TCP/IP和串行(RS232/RS422/RS485)通信功能提供所有机架监控值和状态的扩展通信功能,以便与过程控制和其他自动化系统集成。它还允许与3500机架组态软件和数据采集软件进行以太网通信。支持的协议包括:Modicon Modbus协议(通过串行通信)Modbus/TCP协议(用于TCP/IP以太网通信的串行Modbus的变体)专有Bently Nevada协议(用于与3500机架配置和数据采集程序包通信)3500/92的以太网连接是10BASE-T星形配置以太网的RJ45连接。3500/92支持通信接口,
通信协议和其他功能
原始3500/90,主要值除外
Modbus寄存器。3500/92现在具有可配置
Modbus寄存器实用程序,可提供相同功能
初由主值处理的功能
Modbus寄存器。